MEDRAD® Mark 7 Arterion Angiography Injection System
MEDRAD® Mark 7 Arterion is Bayer’s advanced angiography injection system, specifically designed for DSA procedures, including cardiovascular, neurovascular, and peripheral interventions. With over 50 years of innovation in angiography, MEDRAD continues to set the global standard in contrast injection technology.
KEY FEATURES:
1. Ergonomic Design
- Color touchscreen display showing injection protocols, contrast delivery, and injection results
- Stores up to 35 injection protocols and 50 recent injection results
- Convenient injector head handle and large transport handle
- Large, smooth-rolling lockable casters for easy mobility
- 32% lighter and 20% smaller than MEDRAD® Mark V ProVis
2. One-Hand Syringe Installation with Twist & Go
- Clear polycarbonate syringe barrel and high-pressure tubing for visibility of contrast media and air
- MEDRAD® Twist & Go system enables fast, one-handed syringe installation
- Reduces preparation time and streamlines workflow
3. Powerful Injection Performance
- Flow rate: 0.1–45.0 mL/s (fixed flow) and 0.1–59.9 mL/s (variable flow, optional VFlow software)
- Injection volume: 1–150 mL
- Pressure limit: up to 1200 psi (8273 kPa)
- Up to 4 programmable phases delivered in a single continuous injection
4. Safety and Precision
- Real-time pressure monitoring
- Structured protocol management to reduce variability and human error
- Sterile, single-use disposables for maximum patient safety
5. Multiple Configurations for Angiography Suites
MEDRAD® Mark 7 Arterion offers flexible installation options:
- Pedestal configuration (mobile floor stand with casters)
- Height-adjustable pedestal
- OCS (Overhead Counterpoise System)
- Table mount
- Wall mount
- Dual display configuration options
Each angiography suite is unique. Mark 7 Arterion allows users to configure the system to optimize workflow and imaging environment. According to an international customer satisfaction survey, 97% of users rated overall performance positively and would recommend or repurchase MEDRAD® Mark 7 Arterion.

CLINICAL APPLICATIONS:
- Neuro angiography
- Coronary angiography and cardiac interventions
- Peripheral angiography
- Visceral angiography
- High-precision DSA procedures require accurate high-speed injection
DISTRIBUTOR:
HDN INVESTMENT JOINT STOCK COMPANY
Head Office: 3rd Floor, HH2 Bac Ha Building, 15 To Huu Street, Thanh Xuan Ward, Hanoi, Vietnam
Tel: (+84) 24 3537 7463 - (+84) 916 725 791 (Mr. Hung)
Ho Chi Minh City Branch: No. 541/107 Huynh Van Banh Street, Phu Nhuan Ward, Ho Chi Minh City, Vietnam
Tel: (+84) 28 3520 0039 - (+84) 964 835 266
Nghe An Branch: No. 39 Le Hong Phong Street, Thanh Vinh Ward, Nghe An Province, Vietnam
Tel: (+84) 238 368 3333
Da Nang Office: No. 2 Le Dinh Ly Street, Thanh Khe District, Da Nang City, Vietnam
Tel: (+84) 935 017 678
Email: ctyhdn@fpt.vn | Website: http://hdn.com.vn | Fanpage: Facebook.com/congtyhdn
